Publications
Publications by Research Area
Pulse Pressurization: A Technique for Measuring Building Air Leakage. Berkeley: Lawrence Berkeley Laboratory, 1987. LBID-1321.
. New Technologies for Residential HVAC Ducts. 1995. LBL-35445.
. Leakage Diagnostics, Sealant Longevity, Sizing and Technology Transfer in Residential Thermal Distribution Systems; Part II. Berkeley: Phase VI Report to CIEE, 1999. LBL-42691.
. Leakage Diagnostics, Sealant Longevity, Sizing and Technology Transfer in Residential Thermal Distribution Systems. 1998. LBNL-41118.
. Heat-Flow Measurements in Buildings. Berkeley: Lawrence Berkeley Laboratory, 1984. LBL-17376.
. Field Investigation of Duct System Performance in California-Light Commercial Buildings. 1997. LBNL-40102.
. Energy Impacts of Efficient Refrigerators in the Pacific Northwest. Berkeley: Lawrence Berkeley Laboratory, 1985. LBL-19571.
. Efficient Thermal Energy Distribution in Commercial Buildings. 1999. LBNL-41365.
. Effects of Duct Improvement and ENERGYSTAR Equipment on Comfort and Energy Efficiency. 2000. LBNL-43723.
. Effects of air infiltration on the effective thermal conductivity of internal fiberglass insulation and on the delivery of thermal capacity via ducts. 2000. LBNL-42499.
. Development and Implementation of Survey Techniques for Assessing In-Situ Appliance Efficiencies. Berkeley: Lawrence Berkeley Laboratory, 1986. LBL-23455.
. Commercial Thermal Distribution Systems FINAL REPORT for California Institute for Energy Efficiency. 1997. LBNL-40105.
. Building Energy Retrofit Research: Multifamily Sector. Washington DC: U.S. Department of Energy, 1985.
. "Uncertainty in Fan Pressurization Measurements." . Airflow Performance of Envelopes, Components and Systems STP 1255 (1994) 262-283. LBL- 32115.
. "Signal Attenuation Due to Cavity Leakage." Journal of Acoustical Society of America 84.6 (1988). LBNL-24289.
. "Sealing Ducts in Large Commercial Buildings with Aerosolized Sealant Particles." Energy & Buildings 34.7 (2001) 705-714. LBNL-42414.
. "A Predictive Air Infiltration Model—Long-Term Field Test Validation." ASHRAE Transactions 88.1 (1982). LBL-13509.
. "Performance of thermal distribution systems in large commercial buildings." Energy and Buildings 34 (2002) 215-226. LBNL-44331.
. "Particle Deposition in a Two Dimensional Slot from a Transverse Stream." Aerosol Science and Technology 28 (1998) 235-246.
. "Low Frequency Measurement of the Leakage of Enclosures." Rev. Scientific Instruments 57.7 (1986) 1427. LBL-20121.
. "Laboratory and Field Testing of an Aerosol-Based Duct-Sealing Technology for Large Commercial Buildings." ASHRAE Transactions (2002). LBNL-44220.
. "In-Situ Measurements of Wall Thermal Performance: Data Interpretation and Apparatus Design Recommendations." Thermal Insulation, Materials and Systems, (Powell/Mathews Eds.) STP:922 (1987) 91-106. LBL-17773.
. "Infiltration Using the LBL Infiltration Model." Measured Air Leakage Performance of Buildings, (Trechsel/Lagus Ed.) STP:904 (1986) 325 - 347. LBL-17001.
. "Field Measurements of the Interactions between Furnaces and Forced Air Distribution Systems." ASHRAE Transactions 104 (1998) 1805-1816. LBNL-40587.
. "Exterior Exposed Ductwork: Delivery Effectiveness and Efficiency." ASHRAE Transactions 104 (1998) 709-721. LBNL-39083.
.