Thermal Performance Measurements of Sealed Insulating Glass Units with Low-E Coatings Using the MoWitt Field Test Facility
Publication Type
Conference Paper
Date Published
01/1987
Authors
Abstract
Using data obtained in a mobile field-test facility, measured performance of clearsand low-emissivity double-glazing units is presented for south-facing and north-facingsorientations. The changes in U-value and shading coefficient resultingsfrom addition of the low-E coating are found to agree with theoretical expectationssfor the cold spring test conditions. Accurate nighttime U-values weresderived from the data and found to agree with calculations. Expected correlationsbetween U-value and wind speed was not observed in the data; a plausible experimentalsreason for this is advanced.
Journal
ASHRAE Winter Meeting, Symposium on Fenestration Performance
Year of Publication
1987
Organization
Building Technologies Department, Building & Industrial Energy Systems Division, Windows and Envelope Materials